Daikin FBA85BVMA 8.5kW Premium Slimline Ducted Air Conditioner
The Daikin FBA85BVMA Premium Slimline ducted system combines 8.5kW rated cooling capacity with 10.0kW rated heating capacity. This equipment combination pairs the FBA85BVMA indoor unit with the RZAV85C2V1 outdoor unit and the BRC1E63 wired wall controller. It features inverter technology, reverse-cycle operation, R32 refrigerant and a single-phase power supply.
Designed for concealed ceiling-space installation, a ducted system delivers conditioned air through a network of ducts and outlets. This approach allows the indoor equipment to remain out of everyday view while providing heating and cooling to the areas included in the installation design. Correct equipment selection and thoughtful duct planning are essential to achieving a comfortable result.
Daikin FBA85BVMA Equipment Combination
This listing identifies the indoor model, outdoor model and controller together so you can request a quotation for a clearly defined combination. Keeping the complete model numbers on your quotation makes it easier to compare offers and confirm that the proposed equipment matches your requirements.
Before ordering, ask your installer to assess the property and confirm the installation scope. The air conditioning equipment forms one part of a completed ducted installation. Ducts, outlets, return-air components, electrical work, refrigerant pipework and other installation materials must also be considered.
Technical Specifications
| Brand | Daikin |
|---|---|
| Range | Premium Inverter Slimline Ducted |
| Indoor model | FBA85BVMA |
| Outdoor model | RZAV85C2V1 |
| Controller | BRC1E63 wired wall controller |
| Rated cooling capacity | 8.5kW |
| Rated heating capacity | 10.0kW |
| Operation | Reverse cycle: heating and cooling |
| Technology | Inverter |
| Refrigerant | R32 |
| Power supply | Single phase, 220–240V, 50Hz |
| Indoor dimensions, H × W × D | 245 × 1400 × 800mm |
| Indoor weight | 47kg |
| Outdoor dimensions, H × W × D | 990 × 940 × 320mm |
| Outdoor weight | 78kg |
Low-Profile Indoor Unit for Ceiling Spaces
The Daikin FBA85BVMA has a low-profile indoor cabinet that can be considered for projects where available ceiling height is a concern. Its width and depth must also be checked carefully against the proposed installation location, structural members and the route used to bring the equipment into position.
Cabinet dimensions do not represent the total installation space required. Your installer needs to allow room for duct connections, supports, drainage, insulation, electrical connections and service access. The equipment location should be assessed as part of the complete system layout.
Daikin specifies ceiling-space installation for these R32 ducted indoor units; they are not intended for underfloor installation. For renovations, arrange a site inspection before purchasing. For new buildings, discuss equipment placement and access panels while the ceiling layout can still be coordinated with other services.
Reverse-Cycle Comfort Through the Seasons
The Daikin FBA85BVMA provides cooling and heating through the same ducted installation. Reverse-cycle operation gives you a central system for managing seasonal temperature changes in the areas covered by the duct design.
When considering your requirements, explain how the property is occupied throughout the day. A home office used during working hours may have different comfort priorities from bedrooms used mainly at night. These details help your installer understand the operating pattern the system needs to support.
The appropriate capacity depends on the building rather than a simple room count. Window area, ceiling height, insulation, orientation, shading and internal heat sources all influence the heating and cooling load. Ask for an assessment that considers these factors before confirming the equipment selection.
Premium Inverter Technology
The Daikin FBA85BVMA combination uses inverter technology, allowing compressor output to vary with demand within the equipment’s operating limits. This is relevant when indoor conditions and the required heating or cooling output change during operation.
Actual electricity consumption will depend on the installation, weather, temperature settings and usage. Rated heating or cooling capacity should not be interpreted as the amount of electricity the equipment continuously consumes. Capacity and electrical input describe different aspects of system performance.
For practical advice about operation, discuss your preferred temperature settings and expected operating hours with the installer. Good insulation, appropriate shading and a properly designed duct network also contribute to the overall result.
Single-Phase Power Supply
This Daikin FBA85BVMA listing uses the single-phase RZAV85C2V1 outdoor model. Confirm the available power supply at your property before ordering, especially if you are replacing equipment with a different model or electrical arrangement.
A qualified electrician should assess the required circuit, cabling, protection and isolation against the installation instructions. An existing air conditioning circuit should be checked for suitability rather than assumed appropriate because it previously supplied another system.
Discreet Ducted Air Distribution
A Daikin FBA85BVMA ducted installation can be planned around the interior layout, with supply-air outlets positioned to serve the selected areas. This offers an opportunity to coordinate visible grilles and diffusers with ceiling finishes, lighting and furniture placement.
The position of each outlet affects how air moves through a room. Return-air placement is equally important because the installation needs an effective path for air to travel back to the indoor equipment. These decisions should be considered together during system design.
Let your installer know about large windows, rooms exposed to afternoon sun or areas with unusual ceiling heights. Different rooms may require different airflow allocations, even when their floor areas are similar.
BRC1E63 Wired Wall Controller
The Daikin FBA85BVMA equipment combination includes the BRC1E63 wired wall controller. A dedicated wall-mounted interface provides a convenient location for managing compatible system operation.
Agree on the controller position before installation begins. It should be accessible and easy to read in normal use. If you need additional control options, ask the installer to identify the compatible accessories and explain precisely which functions will be available.
Optional Zoning and Additional Controls
If you want zoning with the Daikin FBA85BVMA, have the proposed arrangement assessed alongside the duct design. Zoning requires suitable additional components and must maintain the airflow required by the air conditioning equipment.
Describe which areas you expect to operate together and which rooms you would like to manage separately. This gives the installer useful information when assessing zone sizes, damper arrangements and control compatibility.
Zoning hardware, additional controllers and remote-access accessories should be itemised in the quotation where required. They should not be assumed included simply because the equipment is a ducted system or is supplied with a wired controller.
Installation Design and Existing Ductwork
For a replacement installation, the Daikin FBA85BVMA should be assessed against the condition and suitability of the existing duct network. Reusing ducts may be possible in some projects, but their dimensions, insulation, layout and overall condition need checking.
Ask whether the quotation includes changes to return-air components, outlet positions or duct branches. Existing arrangements may need modification to suit the new equipment or to address comfort issues experienced with the previous installation.
Provide a floor plan and explain any rooms that have been difficult to heat or cool. Photographs of existing access points and equipment locations can also help establish the scope, although they do not replace a site assessment where one is needed.
Outdoor Unit Placement
The Daikin FBA85BVMA is paired here with the RZAV85C2V1 outdoor unit. Its location must provide the support, ventilation, clearances and access required by the manufacturer’s installation instructions.
Discuss nearby windows, pathways, fences and other equipment when selecting the position. The installer should also assess refrigerant pipe routing, electrical access and any heating-mode drainage provisions relevant to the site.
Clear Quotation and Installation Scope
A useful quotation identifies both the equipment and the work needed to complete the installation. Ask for clear details covering ductwork, outlets, return air, refrigerant piping, drainage, electrical work, mounting arrangements and commissioning.
If the project involves removing an existing system, confirm whether removal and disposal are included. Access restrictions, building modifications and optional accessories should also be recorded where applicable. A written scope helps you compare quotations on a consistent basis.
Professional Installation and Handover
Have the Daikin FBA85BVMA installed by appropriately qualified professionals following the applicable manufacturer instructions. Confirm that the relevant refrigerant and electrical work will be completed by people holding the required qualifications.
At handover, ask for operating guidance, installation documentation and current warranty information. Keep your purchase and service records. Warranty eligibility, conditions and exclusions should be confirmed before purchase rather than inferred from general advertising.
Maintenance and Service Access
Concealed equipment still requires accessible maintenance points. Plan access to the return-air filter and indoor service area before the ceiling finishes are completed, and ask the installer to explain how routine care will be carried out.
Follow the operating instructions for filter maintenance and arrange professional servicing appropriate to the installation and usage. Keep air outlets unobstructed and contact a qualified technician if you notice unusual operation or a persistent change in performance.
Explore the Daikin Ducted Range
Visit the official Daikin ducted air conditioning website for further manufacturer information. You can also browse our air conditioning range when comparing equipment options for your project.
Request a Quote for the Daikin FBA85BVMA
Contact Aircon Trade with your property location, floor plan and preferred installation timeframe. Include the model numbers of any existing system and details of the areas you want conditioned.
Use our contact page to request a quote. Confirm the final equipment combination, installation scope and optional accessories before ordering so the proposed solution matches your project requirements.
Capacities are manufacturer-rated values. Suitability, availability, installation requirements, accessories and pricing are subject to assessment and quotation. Product images are representative illustrations.





Reviews
There are no reviews yet.