Daikin FDYA71AV19 / RZAS71C2V1 7.1kW Premium Inverter Ducted System – R32 Single Phase

Daikin FDYA71AV19 / RZAS71C2V1 7.1kW Premium Inverter Ducted System – R32 Single Phase

Including GST

The Daikin FDYA71AV19 / RZAS71C2V1 7.1kW Premium Inverter Ducted System – R32 Single Phase provides discreet reverse-cycle heating and cooling through a concealed indoor unit and professionally designed ductwork.

  • 7.1kW rated cooling capacity
  • 7.5kW rated heating capacity
  • FDYA71AV19 concealed ducted indoor unit
  • RZAS71C2V1 single-phase outdoor unit
  • R32 refrigerant and Premium Inverter technology
  • BRC1E63 Nav Ease wired wall controller
  • Single-phase power supply: 220–240V, 50Hz
  • Optional zoning and Wi-Fi accessories, subject to compatibility and quotation

Request a quote from Air Conditioning Trade for equipment pricing, availability and delivery. Installation and additional accessories are subject to the confirmed quotation.

Our Payment Methods
Compare

Daikin FDYA71AV19 Single Phase 7.1kW Ducted Air Conditioner

The Daikin FDYA71AV19 Single Phase Premium Inverter ducted air conditioner provides reverse-cycle heating and cooling through a concealed indoor unit. Paired with the matching RZAS71C2V1 outdoor unit, this combination delivers 7.1kW rated cooling capacity and 7.5kW rated heating capacity. The package specified for this listing also includes the BRC1E63 Nav Ease wired wall controller.

A ducted installation distributes conditioned air through a network of ducts connected to outlets in the selected rooms. This arrangement suits projects where a discreet interior appearance is important. Instead of placing the main indoor equipment within the occupied room, the unit is concealed in a suitable ceiling or services space, with access retained for maintenance.

Complete FDYA71AV19 and RZAS71C2V1 Combination

This listing identifies the FDYA71AV19 indoor unit, RZAS71C2V1 outdoor unit and BRC1E63 wired controller together so customers and installers can confirm the equipment being quoted. It is a single-phase, R32 reverse-cycle combination from Daikin’s Premium Inverter Ducted range.

When comparing quotations, check the complete model numbers rather than the cooling capacity alone. Different Daikin ranges and electrical configurations can have similar capacity ratings while using different equipment. The written quotation should identify the indoor unit, outdoor unit, controller and any requested accessories so the supplied package is clear before an order is placed.

Key Product Specifications

Brand Daikin
Product Range Premium Inverter Ducted
Indoor Unit FDYA71AV19
Outdoor Unit RZAS71C2V1
Controller BRC1E63 Nav Ease wired wall controller
Rated Cooling Capacity 7.1kW
Rated Heating Capacity 7.5kW
Refrigerant R32
Power Supply Single phase, 220–240V, 50Hz
System Type Reverse-cycle Premium Inverter ducted air conditioner

Premium Inverter Performance

The Daikin FDYA71AV19 Single Phase system uses inverter operation to vary compressor output as the demand for heating or cooling changes. Correct sizing and commissioning help the equipment respond to the building’s requirements. The rated capacities describe performance under specified test conditions and should not be interpreted as a guaranteed output in every installation or weather condition.

For a useful comparison between systems, consider the property’s actual heating and cooling requirements alongside the equipment specifications. Ask your installer to explain how the proposed capacity relates to the rooms being conditioned, the intended zone combinations and the local climate. This gives you a clearer basis for choosing equipment than selecting a model from its capacity label alone.

Single-Phase Electrical Requirements

This combination requires a single-phase 220–240V, 50Hz electrical supply. A licensed electrician should assess the available electrical service, switchboard and proposed circuit before installation. Existing single-phase power at the property does not, by itself, establish that the current wiring and circuit protection are suitable for the new air-conditioning equipment.

The electrical scope should be clearly itemised in the installation quotation. It may involve cabling, circuit protection, isolation and other work identified during the site assessment. Customers should confirm who is responsible for these tasks and whether any switchboard alterations are required. Electrical installation must follow the manufacturer’s requirements and applicable Australian rules.

Discreet Ducted Comfort

The concealed indoor design allows heating and cooling to reach selected rooms without separate wall-mounted indoor units throughout the property. In a typical ceiling installation, the supply-air outlets, return-air grille and controller are the main visible indoor components. Outlet placement can be coordinated with the room layout as part of the installation design.

Before choosing a ducted system, the installer should inspect the available space and access route. The equipment needs appropriate installation and servicing clearance, while the ducts require enough room to be routed correctly. Existing structural elements, lighting, plumbing and other services may influence the final layout. Planning these details early helps establish a realistic installation scope.

Optional Zoning and Controls

A compatible zoning arrangement can divide the duct network into selected areas, allowing zone dampers to open or close according to the chosen control system. For example, a professionally designed arrangement may separate living spaces from bedrooms. The number and size of zones should be determined from the property layout and the system’s airflow requirements.

Closing zones does not automatically mean that any remaining room can operate on its own. The installer must establish permitted zone combinations and maintain the airflow required by the equipment. Zone motors, sensors, control boards and additional controllers are separate components unless included in the quotation. Confirm their compatibility and intended operation before purchasing accessories.

BRC1E63 Wired Controller

The specified BRC1E63 Nav Ease controller provides a fixed wall-mounted control point with a clear, backlit display and weekly scheduling. It also offers functions such as temperature-limit settings, a countdown timer, key lock and fault self-diagnosis. The functions available in a particular installation depend on the connected equipment and configuration.

Discuss the proposed controller position with your installer so it is convenient to reach and use. Ask for a demonstration of temperature selection, operating modes and scheduling when the system is handed over. The BRC1E63 is a wired controller; it should not be described as providing built-in Wi-Fi or a complete zoning solution without the necessary additional equipment.

Professional System Design

A ducted installation requires coordinated planning of the equipment, ducts, outlets, return air, refrigerant pipework, drainage and electrical connections. A heat-load assessment should consider insulation, ceiling height, window area, orientation, occupancy and the rooms that will operate together. These factors can change the required capacity substantially, even between properties with similar floor areas.

Duct sizing and airflow balancing are also important. The installer should select appropriate duct routes and outlet locations rather than simply connecting the new unit to whatever arrangement is already present. For replacement projects, existing ducts and accessories should be assessed for their condition and suitability. Reuse should be confirmed through the installation design rather than assumed.

Outdoor-Unit Placement

The RZAS71C2V1 outdoor unit should be positioned with the airflow clearances and servicing access required by Daikin. The installer must assess the proposed mounting surface, nearby obstructions and the route between the indoor and outdoor equipment. Placement decisions should account for the property’s layout and practical access for future inspections or repairs.

Discuss the outdoor location before accepting an installation quotation. Ask how the equipment will be supported, where pipework will run and how the installation will fit around paths, fences and other services. A clear site plan can help avoid misunderstandings about the finished appearance and identify additional materials or work before installation begins.

What Is Included?

The equipment package specified for this listing consists of the FDYA71AV19 concealed indoor unit, RZAS71C2V1 outdoor unit and BRC1E63 Nav Ease wired controller. The accepted quotation confirms the final supplied items, their quantities and any additional accessories requested for the project.

Ductwork, supply-air outlets, return-air grilles, zoning equipment, Wi-Fi interfaces, refrigerant pipework, drainage materials, electrical work, mounting hardware, delivery and installation are additional unless expressly itemised. When comparing prices, check these inclusions carefully so you are comparing equivalent scopes. An equipment-only quotation and a complete installed-system quotation cover different work.

Product images are illustrative representations and may differ from the exact cabinet details, labels, dimensions or controller appearance of the supplied equipment. Use the written model numbers, official technical documentation and accepted quotation to confirm the product. Image proportions should not be used to calculate installation space or clearances.

Professional Installation and Warranty

The Daikin FDYA71AV19 Single Phase system should be installed and commissioned by appropriately licensed professionals following Daikin’s instructions and applicable Australian requirements. Commissioning should establish that the installation operates correctly, and the customer should receive relevant documentation and an explanation of the controls before handover.

Manufacturer warranty coverage is subject to Daikin Australia’s applicable terms and the installation’s use and circumstances. Confirm the relevant coverage when requesting a quotation, particularly if the equipment is intended for a commercial application. Any installer workmanship warranty should be identified separately so responsibility for equipment and installation issues is clear.

For manufacturer information, visit the official Daikin Premium Inverter Ducted page. You can also browse our air-conditioning systems or contact Air Conditioning Trade for assistance.

Routine Care and Everyday Use

Follow the supplied operating instructions and your installer’s maintenance guidance. Ask where the return-air filter is located, how it should be cleaned and how often it should be checked for your household conditions. Keep outlets clear of obstructions and arrange professional servicing when required. Do not open electrical or refrigerant components yourself.

Use the controller’s schedule to suit your routine and discuss sensible temperature settings with your installer. Building insulation, shading and closed external doors can influence the heating and cooling demand. If comfort changes noticeably or a fault indication appears, record the symptoms and contact a qualified service professional rather than repeatedly changing settings without identifying the cause.

Request a Quote for the Daikin FDYA71AV19 Single Phase

Contact Air Conditioning Trade for pricing and availability on the Daikin FDYA71AV19 Single Phase 7.1kW Premium Inverter Ducted System. Provide your project location, whether it is a new installation or replacement, and the accessories you require. This information helps establish a clear equipment and delivery quotation.

Before placing an order, confirm the proposed system with your installation professional and check the complete model numbers against the quotation. A clearly defined scope helps you understand what is supplied, what additional work is required and how the system will serve the selected rooms in your property.

Reviews

There are no reviews yet.

Be the first to review “Daikin FDYA71AV19 / RZAS71C2V1 7.1kW Premium Inverter Ducted System – R32 Single Phase”

Your email address will not be published. Required fields are marked *

Scroll to Top