Daikin FBA140BVMA Three Phase 14kW Premium Slimline Ducted System
The Daikin FBA140BVMA Three Phase Premium Slimline ducted system provides 14.0kW rated cooling capacity and 16.5kW rated heating capacity. This combination pairs the FBA140BVMA indoor unit with the RZAV140F2Y1 outdoor unit and BRC1E63 wired wall controller. It features inverter technology, reverse-cycle operation and R32 refrigerant.
A ducted installation distributes conditioned air through a network of ducts and outlets while concealing the indoor equipment in the ceiling space. This allows heating and cooling to be planned around selected areas of a property while maintaining a consistent interior appearance. Equipment sizing, airflow distribution and installation access should be assessed together when planning the system.
Daikin FBA140BVMA Three Phase Equipment Combination
This listing identifies the indoor unit, outdoor unit and controller together so you can request a quotation for a clearly defined combination. Use the complete model numbers when discussing installation requirements, comparing offers or arranging a replacement for existing equipment.
The outdoor model identifies the electrical version included in this listing. Ask your installer to record RZAV140F2Y1 on the quotation and confirm the available power supply before ordering. A clear equipment schedule helps ensure the quoted combination matches the requirements of the project.
Technical Specifications
| Brand | Daikin |
|---|---|
| Range | Premium Inverter Slimline Ducted |
| Indoor model | FBA140BVMA |
| Outdoor model | RZAV140F2Y1 |
| Controller | BRC1E63 wired wall controller |
| Rated cooling capacity | 14.0kW |
| Rated heating capacity | 16.5kW |
| Operation | Reverse cycle: heating and cooling |
| Technology | Inverter |
| Refrigerant | R32 |
| System power supply | Three phase, 380–415V, 50Hz |
| Indoor dimensions, H × W × D | 245 × 1400 × 800mm |
| Indoor unit weight | 47kg |
| Outdoor dimensions, H × W × D | 870 × 1100 × 460mm |
| Outdoor unit weight | 95kg |
Low-Profile Indoor Unit for Ceiling Spaces
The Daikin FBA140BVMA Three Phase system uses a low-profile indoor cabinet that can be considered where available ceiling height is restricted. Its width and depth must also be checked against structural members, existing services and the proposed duct connections.
Cabinet dimensions are only one part of the space assessment. Installation requires suitable allowances for supports, drainage, refrigerant pipes, insulation, electrical connections and service access. Your installer should assess the complete arrangement before confirming the equipment location.
Daikin specifies ceiling-space installation for these R32 ducted indoor units; they are not intended for underfloor installation. For renovations, arrange an inspection before purchasing. For new buildings, coordinate the equipment position and access panels with the ceiling plans early.
Reverse-Cycle Heating and Cooling
The Daikin FBA140BVMA Three Phase combination provides heating and cooling through the same ducted installation. This gives you a central air conditioning option for seasonal comfort in the areas included in the system design.
Explain how the property is occupied when discussing your requirements. Bedrooms used mainly at night may have different priorities from living areas or a home office occupied during the day. The intended operating pattern helps your installer assess airflow distribution and control requirements.
The appropriate capacity depends on the building’s heating and cooling load. Insulation, glazing, orientation, shading, ceiling height and occupancy all influence that load. A room count or a simple floor-area estimate should not replace a properly considered assessment.
Premium Inverter Technology
The Daikin FBA140BVMA Three Phase combination uses inverter technology, allowing compressor output to vary with demand within the equipment’s operating limits. The required heating or cooling output can change as indoor conditions and outdoor temperatures change.
Actual electricity consumption depends on the completed installation and how it is operated. Rated heating and cooling capacities describe thermal output under specified test conditions; they should not be interpreted as continuous electricity consumption figures.
Discuss expected operating hours and preferred temperature settings with your installer. Appropriate shading, insulation and a well-designed duct network are also relevant when considering the comfort achieved from the installation.
Three-Phase Electrical Requirements
This Daikin FBA140BVMA Three Phase system requires the supply specified for the RZAV140F2Y1 outdoor model. Confirm the property’s available electrical supply and proposed connection arrangement before placing an order.
A qualified electrician should assess the circuit, cabling, protection and isolation requirements against the manufacturer’s installation instructions. If replacing existing equipment, have the electrical infrastructure checked for suitability rather than assuming that it can be reused.
The installation quotation should identify any electrical work required to complete the project. Confirm connection details with your installer and electrician so the equipment selection and installation scope are coordinated from the outset.
Discreet Ducted Air Distribution
A Daikin FBA140BVMA Three Phase installation can be planned with supply-air outlets positioned around the selected conditioned areas. Visible grilles and diffusers can be coordinated with ceiling finishes, lighting and furniture placement.
Outlet locations should support useful air movement through each room. Return-air placement also requires careful consideration so air has an effective path back to the indoor equipment. Supply and return arrangements should be assessed together during duct design.
Tell your installer about rooms exposed to strong afternoon sun, extensive glazing or unusual ceiling heights. These areas may need different airflow allocations from other rooms, even when their floor areas appear similar.
BRC1E63 Wired Wall Controller
The Daikin FBA140BVMA Three Phase equipment combination includes the BRC1E63 wired wall controller. A dedicated wall-mounted interface provides an accessible location for managing compatible system operation.
Agree on the controller position before installation begins. Consider visibility and convenient access for the people using the equipment. If additional control functions are required, ask your installer to identify compatible accessories and explain precisely how the completed installation will operate.
Optional Zoning and Additional Controls
If you are considering zoning with the Daikin FBA140BVMA Three Phase system, request an assessment alongside the duct design. The proposed arrangement must use suitable components and maintain the airflow required by the air conditioning equipment.
Explain which rooms you want to operate together and which areas you would prefer to manage separately. Your installer can assess zone sizes, damper arrangements and control compatibility against your intended usage.
Zoning hardware, additional controllers and remote-access accessories should be itemised separately where required. Their inclusion should be confirmed in the quotation rather than assumed from the presence of a standard wired controller.
Duct Design and Replacement Planning
When considering the Daikin FBA140BVMA Three Phase combination for a replacement installation, have the existing duct network inspected. Duct dimensions, insulation, condition and layout all influence whether existing components can be reused.
The duct design should suit the selected equipment and the building layout. Duct lengths, bends, branches, outlets and return-air arrangements affect how air reaches each room. These details deserve attention alongside the nominal equipment capacity.
Provide a floor plan where available and identify any areas that have been difficult to heat or cool. Photographs of existing equipment and access points can support an initial discussion, although a site inspection may still be needed to confirm the installation scope.
Outdoor Unit Placement and Access
The Daikin FBA140BVMA Three Phase system is paired here with the RZAV140F2Y1 outdoor unit. Its proposed location should provide suitable support, ventilation, installation clearances and access for future servicing.
Discuss nearby windows, paths, fences and other equipment when selecting the position. The installer should assess refrigerant pipe routing, electrical access and any heating-mode drainage provisions relevant to the site. Cabinet dimensions alone do not establish the total space required.
Understanding Your Installation Quotation
A useful quotation identifies both the equipment and the work needed to complete the installation. Ask whether it includes ductwork, outlets, return-air components, refrigerant piping, drainage, electrical work, mounting arrangements and commissioning.
For replacement projects, confirm whether removal and disposal of the existing equipment are included. Access restrictions, building modifications and optional accessories should also be recorded where applicable. A clear scope helps you understand the final price and compare quotations consistently.
Professional Installation and Handover
Arrange installation of the Daikin FBA140BVMA Three Phase system through appropriately qualified professionals following the applicable manufacturer instructions. Refrigerant handling and electrical work should be completed by people holding the relevant qualifications.
At handover, request operating guidance and the appropriate installation documentation. Confirm current manufacturer warranty terms, eligibility and exclusions before purchase. Retain your purchase records, installation details and service documentation for future reference.
Maintenance and Service Access
Plan practical access to the return-air filter and indoor service area before surrounding ceilings and finishes are completed. Concealed equipment still requires maintenance, and suitable access helps make routine care and professional servicing easier to arrange.
Follow the operating instructions for filter maintenance and discuss servicing requirements with your installer. Keep air outlets unobstructed and contact a qualified technician if you notice unusual operation or a persistent change in performance.
Explore Daikin Ducted Air Conditioning
Visit the official Daikin ducted air conditioning website for further manufacturer information. You can also browse our air conditioning range to compare equipment options for your project.
Request a Quote for the Daikin FBA140BVMA Three Phase System
Contact Aircon Trade with your property location, floor plan and preferred installation timeframe. Include the model numbers of any existing equipment and explain which areas you want conditioned.
Use our contact page to request a quote for this three-phase Premium Slimline ducted combination. Confirm the final equipment selection, installation scope and optional accessories before ordering.
Capacities are manufacturer-rated values. Suitability, availability, installation requirements, accessories and pricing are subject to assessment and quotation. Product images are representative illustrations.





Reviews
There are no reviews yet.